This site and contents herein are ©1998-2007, UltraVolt, Inc.



MTBFs
Mean Time Before Failure Report

The intent of this report is to provide our customers with data that substantiates the calculated long-term reliability of the products manufactured by UltraVolt, Inc.

An MTBF analysis of the "-F" Option for a power supply has been performed by taking the sum of the reciprocals of each of the power supply’s MTBF’s at similar conditions.

Calculations were done on nine environments; ground benign, fixed and mobile at 3 temperatures, 21°, 55°, and 65°C and are summarized as follows:


Temp

21°C
55°C
65°C

21°C
55°C
65°C

21°C
55°C
65°C

Environment

Ground Benign
Ground Benign
Ground Benign

Ground Fixed
Ground Fixed
Ground Fixed

Ground Mobile
Ground Mobile
Ground Mobile
Calculated MTBF
(in hours)

32,909,987
14,141,144
10,988,105

6,046,077
2,114,012
1,564,311

1,970,274
799,757
612,843

This report is issued for general sales use and has been edited to maintain UltraVolt's corporate policy on confidential information. Full reports are maintained at UltraVolt in the Quality files.