Mean Time Before Failure Report
The intent of this report is to provide our customers with data that substantiates the calculated long
term reliability of the products manufactured by UltraVolt, Inc.
An MTBF analysis has been performed upon the 1/2C24-N60 power supply based upon the factors enumerated below:
Failure rates from MIL HDBK 217F, Notice 2
A series reliability model
Redundant paths do exist and would indicate a significant increase in actual reliability although
not evident with MTBF
GB, GF, and GM environments at a temperatures of 21, 55 and 65 degrees Centigrade
Actual power dissipation and electrical stresses
Components stressed at less than 10% are taken at 10%
Failure Modes derived from Failure Mode/Mechanism Distributions (RADC) were utilized in the calculations
and indicated with the acronym (FM) to factor the failure rate for modes which adversely affect the power supply
Several components are used in the standard assemblies but are not used for the operation of this power
supply, such components are labeled (NU), minimal failure rates are taken from MIL HDBK 217 for that part type
Calculations were done on nine environments; ground benign, fixed and mobile
at 3 temperatures, 21°, 55°, and 65°C and are summarized as follows:
Temp
21°C
55°C
65°C
21°C
55°C
65°C
21°C
55°C
65°C |
Environment
Ground Benign
Ground Benign
Ground Benign
Ground Fixed
Ground Fixed
Ground Fixed
Ground Mobile
Ground Mobile
Ground Mobile
|
Calculated MTBF (in hours)
1,338,367
463,096
324,171
232,143
83,828
62,111
116,872
44,444
33,350
|
This report is issued for general sales use and has been edited to maintain
UltraVolt's corporate policy on confidential information. Full reports are
maintained at UltraVolt in the Quality files.
|