Parameter

Specification

Units

Input voltage Vin (pins 1 & 2) 5VDC ±0.5 (recommended) maximum: 12Vdc (reverse: -0.2V) VDC
Input current For 0V output voltage: <1.6
For 100V, no load: <3
At full output voltage, full load: <50
mA
HV output Vout (pin 4) 0 to 100 programmable VDC
Output Power 0 to 100 mW
Polarity Fixed positive or negative -
HV setting (pin 3) Via external voltage source 0/2.5V
Accuracy: ±2% at full scale
-
Max. output current Iout 1 nominal mA
Load voltage regulation ±0.01% of full output voltage for no load to full load -
Line voltage regulation ±0.01% of full output voltage over specified input voltage range -
Residual ripple <50mV peak-to-peak – ripple can be reduced to less than 10mV by adding an external 100nF small CMS capacitor -
Temperature coefficient <50 PPM/°C
Output HV monitoring Not available on this product -
Output reference voltage Not available on this product -
HV power ON/OFF Not available on this product -
Operating temperature -10 to +65, Full load, Max Eout, Case Temp °C
Storage temperature -10 to +70 °C
Safeguards • Output current internally limited
• Soft start feature: low overshoot
-
Shielding Ground return is to metal enclosure -