Parameter |
Specification |
Units |
|||
|
Input voltage Vin (pins 1 & 2) |
5VDC ±0.5 or 12 to 15 ±0.5 |
VDC |
|||
|
Input current |
Inhibition mode: <5 at full output voltage, full load: |
mA |
|||
|
<65 (200Vout) |
<60 (300Vout) |
<55 (400Vout) |
<50 (500Vout) |
mA |
|
|
Polarity |
Fixed positive or negative |
||||
|
Output Voltage |
0 to 200 |
0 to 300 |
0 to 400 |
0 to 500 |
VDC |
|
Output Current |
500 |
330 |
250 |
200 |
uA |
|
HV setting (pin 3) |
Via external potentiometer, minimum resistance 10kΩ or Via external voltage source 0/2.5V ±0.5% at full scale, and input impedance >1MΩ |
- |
|||
|
Load voltage regulation |
±0.01% of full output voltage for no load to full load |
- |
|||
|
Line voltage regulation |
±0.01% of full output voltage over specified input voltage range |
- |
|||
|
Residual ripple |
<0.01% peak-to-peak at full output voltage and current |
- |
|||
|
Temperature coefficient |
<50 |
PPM/°C |
|||
|
Output HV monitoring (pin 2) |
0/2.5V signal Accuracy : ±0.2% Output impedance : 1kΩ |
- |
|||
|
Output reference voltage (pin 4 - optional) |
2.5V ±0.5%, TC:50ppm/°C, Max. output current : 1mA |
- |
|||
|
HV power ON/OFF (pin 5) |
ON: 0 volt, connected to ground OFF: not connected Open collector compatible |
- |
|||
|
Operating temperature |
-10 to +65, Full load, Max Eout, Case Temp |
°C |
|||
|
Storage temperature |
-40 to +70 |
°C |
|||
|
Safeguards |
Output current internally limited Soft start feature: the start is guaranteed with no overshoot |
- |
|||