PARAMETER

SPECIFICATION

UNITS

Input voltage Vin (pins 1 & 2)

12 ±0.5, 15 ±0.5, or 24 ±1

VDC

Input current

No load: 15, Full load: from 65 to 100

mA

Polarity

Fixed positive and fixed negative

-

Output Voltage

0 to 600

0 to 1000

0 to 1250

0 to 1500

VDC

Input Voltage

12

15

24

12

15

24

12

15

24

12

15

24

VDC

Output Power

0.5

0.8

1

0.5

0.8

1

0.5

0.8

1

0.5

0.8

1

W

Output Current

0.83

1.33

1.67

0.5

0.8

1

0.4

0.64

0.8

0.33

0.53

0.67

mA

HV setting (pins 3, 4 & 5)

Via external potentiometer, minimum resistance 10kΩ or

Via external voltage source 0/5V ±0.5% at full scale, and input impedance >1MΩ

-

Load voltage regulation

±0.01% of full output voltage for no load to full load

-

Line voltage regulation

±0.01% of full output voltage over specified input voltage range

-

Residual ripple

<0.01% peak to peak at full load

-

Temperature coefficient

100ppm/°C for the maximum output voltage after starting and over temperature range 0 to 50°C

-

Output HV monitoring (pin 6)

+1V/1kV max. or -1V/-1kV max. according to model polarity

output impedance = 200kΩ ±1%

-

Output reference voltage (pin 5)

5V ±0.5%, TC:50ppm/°C, max. output current: 1mA

-

Operating temperature

-10 to +65, Full Load, Max Eout, Case Temp

°C

Storage temperature

-40 to +70

°C

Safeguards

Arc and short circuit protection

-

Options

• Flying wire for HV output instead of pin 7

• Suitable for use with an external potentiometer

-