Parameter

Conditions

Models

Units

INPUT

All Types

 

Voltage Range

Full Power

24VDC ± 10%

VDC

Current

Standby / Disable

<70 unipolar, <105 bipolar

mA

Current

Full Load, Max Eout

<420

mA

Current

No Load, Max Eout

<400

mA

OUTPUT

 

1kV/±1kV

2kV/±2kV

4kV/±4kV

±5kV

6kV

10kV

 

Power

Nominal Input, Max Eout

0.25

0.5

1

1

1

1

W

Current

Iout Entire Voltage Range

250

250

250

200

167

100

uA

Ripple

Full Load, Max Eout

0.05

0.05

0.05

0.03

0.03

0.01

%V pp

Voltage Monitor

Normal Operating Conditions

0 to 10 ± 0.5%

VDC

Current Monitor

Normal Operating Conditions

0 to 10 ± 0.1%

VDC

Line Regulation

Vin Min to Vin Max, Max Eout

<0.01

%

Load Regulation

No Load to Full Load, Max Eout

<0.01

%

PRogramming & Controls

All Types

 

Input Impedance

Normal Operating Conditions

10

MΩ

Adjust Voltage

Differential

0 to +10

VDC

Enable/Disable

0 to +1 Disable, +2.5 to +15 Enable (Default = Disable)

VDC

Output Voltage

T = +25°C, Initial Value

+10.00 ± 0.05%

VDC

Max Source Current

T = +25°C

1

mA