Parameter |
Conditions |
Models |
Units |
|||||
|
INPUT |
All Types |
|
||||||
|
|
Full Power |
24VDC ± 10% |
VDC |
|||||
|
Current |
Standby / Disable |
<70
unipolar, <105 bipolar |
mA |
|||||
|
Current |
Full Load, Max Eout |
<420 |
mA |
|||||
|
Current |
No Load, Max Eout |
<400 |
mA |
|||||
|
OUTPUT |
|
1kV/±1kV |
2kV/±2kV |
4kV/±4kV |
±5kV |
6kV |
10kV |
|
|
Power |
Nominal Input, Max Eout |
0.25 |
0.5 |
1 |
1 |
1 |
1 |
W |
|
Current |
|
250
|
250
|
250 |
200 |
167 |
100 |
uA |
|
Ripple |
Full Load, Max Eout |
0.05 |
0.05 |
0.05 |
0.03 |
0.03 |
0.01 |
%V pp |
|
Voltage Monitor |
Normal Operating Conditions |
0 to 10 ± 0.5% |
VDC |
|||||
|
Current Monitor |
Normal Operating Conditions |
0 to 10 ± 0.1% |
VDC |
|||||
|
Line Regulation |
Vin Min to Vin Max, Max Eout |
<0.01 |
% |
|||||
|
Load Regulation |
No Load to Full Load, Max Eout |
<0.01 |
% |
|||||
|
PRogramming
& Controls |
All Types |
|
||||||
|
Input Impedance |
Normal Operating Conditions |
10 |
MΩ |
|||||
|
Adjust Voltage |
Differential |
0 to +10 |
VDC |
|||||
|
Enable/Disable |
0 to +1
Disable, +2.5 to +15 Enable (Default = Disable)
|
VDC |
||||||
|
Output Voltage |
T = +25°C, Initial Value |
+10.00 ±
0.05% |
VDC |
|||||
|
Max Source Current |
T = +25°C |
1 |
mA |
|||||