PARAMETER |
CONDITIONS |
MODELS |
UNITS |
|
|
Input POWER |
|
12V
MODELS |
24V
MODELS |
|
|
|
Full Power |
+12 ± 5% |
+24 ± 5% |
VDC |
|
|
Derated |
+10.8 to
+16 |
+21.6 to
+30 |
VDC |
|
Current |
Standby ( Disabled ) |
< 90 |
< 50 |
mA |
|
Current |
No Load |
< 0.15 |
< 0.15 |
A |
|
Current |
Max Load |
< 1.60 |
< 1.40 |
A |
|
AC Ripple Current |
Nominal Input, Full Load |
< 80 |
< 100 |
mA p-p |
|
LOCAL CONTROLS: REFERENCE |
ALL TYPES |
|
||
|
Output Voltage |
T = +25°C, Initial value |
+5.1 ± 1% |
VDC |
|
|
Output Impedance |
T = +25°C |
464 ± 1% |
Ω |
|
|
Stability |
Over full temperature range |
0.2 |
mV/°C |
|
|
LOCAL CONTROLS: LVPS ENABLE / DISABLE |
ALL TYPES |
|
||
|
Power supply on |
Open, or a voltage above TTL high |
+2.4 to
32 |
VDC |
|
|
Power supply off |
Grounded, or a voltage below TTL low |
0 to +
0.7 ± 0.2 (Isink 1mA minimum) |
VDC |
|
|
INPUT / OUTPUT ISOLATION |
12V
MODELS |
24V
MODELS |
|
|
|
Isolation Voltage |
Continuous |
15 |
15 |
kV |
|
Leakage Current |
All inputs to all outputs |
< 10
std, < 100 “-E” |
< 10
std, < 100 “-E” |
nA |
|
Leakage Capacitance |
All inputs to all outputs |
< 40
std, < 50 “-E” |
< 50
std or “-E” |
pF |
|
ISOLATED POWER OUTPUTS |
15FL12-12W |
15FL24-24W |
|
|
|
Output #1 Power |
Nominal input, max Iout |
12 |
24 |
W |
|
Output #1 Voltage |
Nominal input voltage range |
+12 ± 2% |
+24 ± 2% |
VDC |
|
Output #1 Current |
Minimum to Maximum |
0 to 1 |
0 to 1 |
A |
|
Output #1 Line Regulation |
Nominal input range, full load |
< 0.1% |
< 0.1% |
VDC |
|
Output #1 Load Regulation |
No load to full load |
< 0.1% |
< 0.1% |
VDC |
|
Output #1 Ripple |
Full load |
< 2% |
< 1% |
V p-p |
|
Output #2 Voltage |
Nominal input voltage range |
-15 ± 1 |
-15 ± 1 |
VDC |
|
Output #2 Current |
Minimum > Maximum |
0 to 10 |
0 to 10 |
mA |
|
Output #2 Line Regulation |
Nominal input range, full load |
< 0.1% |
< 0.1% |
VDC |
|
Output #2 Load Regulation |
No load to full load |
< 2% |
< 2% |
VDC |
|
Output #2 Ripple |
Full load |
< 2% |
< 2% |
V p-p |
|
Output #3 Voltage |
Nominal input voltage range |
+5.6 ± 5% |
+5.6 ± 5% |
VDC |
|
Output #3 Current |
Minimum > Maximum |
0 to 10 |
0 to 10 |
mA |
|
Output #3 Line Regulation |
Nominal input range, full load |
< 1 % |
< 1 % |
VDC |
|
Output #3 Load Regulation |
No load to full load |
< 1 % |
< 1 % |
VDC |
|
Output #3 Ripple |
Full load |
< 1 % |
< 1 % |
V p-p |
|
ISOLATED CONTROLS: TTL CHANNEL “UP” |
ALL TYPES
WITH “-I/O” OPTION |
|
||
|
Local input |
Source voltage, sink current |
10MΩ
internal pull up to +15V |
VDC |
|
|
Isolated output |
Inverted & buffered TTL |
Open
collector with internal 1kΩ pull up to +5V Can sink
10mA max |
VDC |
|
|
Baud Rate |
Varying duty cycle |
DC to
>300 |
kHz |
|
|
ISOLATED CONTROLS: ANALOG CHANNEL “UP” |
ALL TYPES
WITH “-I/O” OPTION |
|
||
|
Local input voltage |
Range |
0 to + 5 |
VDC |
|
|
Local input impedance |
10 Meg |
Ω |
||
|
Isolated output voltage |
Range |
0 to + 5 |
VDC |
|
|
Isolated output impedance |
Buffered
low impedance |
- |
||
|
Initial offset error |
< ± 1% |
mV |
||
|
Gain error |
Full scale |
< ± 2% |
VDC |
|
|
Linearity error |
0 to full scale |
< ± 1% |
VDC |
|
|
Stability |
30 min. warm-up, per 8 hrs / per day |
<
0.01% / < 0.02% |
VDC |
|
|
Temperature Coefficient |
0 to +55°C |
< ± 50 |
ppm/°C |
|
|
Bandwidth |
Symmetric or asymmetric signal |
DC to 30
(-3dB point is 47 Hz) |
Hz |
|