PARAMETER

CONDITIONS

MODELS

UNITS

Input POWER

 

12V MODELS

24V MODELS

 

Voltage Range

Full Power

+12 ± 5%

+24 ± 5%

VDC

Voltage Range

Derated Power Range

+10.8 to +16

+21.6 to +30

VDC

Current

Standby ( Disabled )

< 90

< 50

mA

Current

No Load

< 0.15

< 0.15

A

Current

Max Load

< 1.60

< 1.40

A

AC Ripple Current

Nominal Input, Full Load

< 80

< 100

mA p-p

LOCAL CONTROLS: REFERENCE

ALL TYPES

 

Output Voltage

T = +25°C, Initial value

+5.1 ± 1%

VDC

Output Impedance

T = +25°C

464 ± 1%

Ω

Stability

Over full temperature range

0.2

mV/°C

LOCAL CONTROLS: LVPS ENABLE / DISABLE

ALL TYPES

 

Power supply on

Open, or a voltage above TTL high

+2.4 to 32

VDC

Power supply off

Grounded, or a voltage below TTL low

0 to + 0.7 ± 0.2 (Isink 1mA minimum)

VDC

INPUT / OUTPUT ISOLATION

12V MODELS

24V MODELS

 

Isolation Voltage

Continuous

15

15

kV

Leakage Current

All inputs to all outputs

< 10 std, < 100 “-E”

< 10 std, < 100 “-E”

nA

Leakage Capacitance

All inputs to all outputs

< 40 std, < 50 “-E”

< 50 std or “-E”

pF

ISOLATED POWER OUTPUTS

15FL12-12W

15FL24-24W

 

Output #1 Power

Nominal input, max Iout

12

24

W

Output #1 Voltage

Nominal input voltage range

+12 ± 2%

+24 ± 2%

VDC

Output #1 Current

Minimum to Maximum

0 to 1

0 to 1

A

Output #1 Line Regulation

Nominal input range, full load

< 0.1%

< 0.1%

VDC

Output #1 Load Regulation

No load to full load

< 0.1%

< 0.1%

VDC

Output #1 Ripple

Full load

< 2%

< 1%

V p-p

Output #2 Voltage

Nominal input voltage range

-15 ± 1

-15 ± 1

VDC

Output #2 Current

Minimum > Maximum

0 to 10

0 to 10

mA

Output #2 Line Regulation

Nominal input range, full load

< 0.1%

< 0.1%

VDC

Output #2 Load Regulation

No load to full load

< 2%

< 2%

VDC

Output #2 Ripple

Full load

< 2%

< 2%

V p-p

Output #3 Voltage

Nominal input voltage range

+5.6 ± 5%

+5.6 ± 5%

VDC

Output #3 Current

Minimum > Maximum

0 to 10

0 to 10

mA

Output #3 Line Regulation

Nominal input range, full load

< 1 %

< 1 %

VDC

Output #3 Load Regulation

No load to full load

< 1 %

< 1 %

VDC

Output #3 Ripple

Full load

< 1 %

< 1 %

V p-p

ISOLATED CONTROLS: TTL CHANNEL “UP”

ALL TYPES WITH “-I/O” OPTION

 

Local input

Source voltage, sink current

10MΩ internal pull up to +15V
<1V low, >2.5V high

VDC

Isolated output

Inverted & buffered TTL

Open collector with internal 1kΩ pull up to +5V

Can sink 10mA max

VDC

Baud Rate

Varying duty cycle

DC to >300

kHz

ISOLATED CONTROLS: ANALOG CHANNEL “UP”

ALL TYPES WITH “-I/O” OPTION

 

Local input voltage

Range

0 to + 5

VDC

Local input impedance

10 Meg

Ω

Isolated output voltage

Range

0 to + 5

VDC

Isolated output impedance

Buffered low impedance

-

Initial offset error

< ± 1%

mV

Gain error

Full scale

< ± 2%

VDC

Linearity error

0 to full scale

< ± 1%

VDC

Stability

30 min. warm-up, per 8 hrs / per day

< 0.01% / < 0.02%

VDC

Temperature Coefficient

0 to +55°C

< ± 50

ppm/°C

Bandwidth

Symmetric or asymmetric signal

DC to 30 (-3dB point is 47 Hz)

Hz