Parameter

Conditions

Models

Units

INput

ALL TYPES

 

Operating Range

All Conditions

+24 ± 10

VDC

Current

Full Load Output

900mA Typical

mA

OutpuT

ALL TYPES

 

Voltage Range

Nominal Input

0 to 5

VDC

DC Current Range

Nominal Input

0 to 3

Amps

Voltage Range

Derated

0 to 5.7

VDC

DC Current Range

Derated

0 to 3.3

Amps

Voltage Monitor Scaling

Full Load

10

VDC

Current Monitor Scaling

Full Load

10

VDC

Programming & Controls

ALL TYPES

 

Input Impedance

Nominal Input

+ Output Models 10MΩ to GND

MΩ

Adjust Resistance

Typical Potentiometer Values

10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)

Adjust Voltage

Referenced to signal ground

0 to +10 VDC

VDC

Accuracy

In current control

±0.1%

Amps

Offset

Voltage control

0.04%

VDC

Offset

Current control

0.001%

Amps

Output Voltage

T=+25°C,  Initial Value

+10.0V ± 0.05%

VDC

Enable/Disable

0 to +0.5 Disable, +2.4 to 10 Enable (Default = Enable)

VDC

ENVIRONMENTAL

ALL TYPES

 

Operating

Full Load, Max Eout, Case Temp.

+10 to +45

°C

Coefficient

Over the Specified Temperature

15

PPM/°C

Thermal Shock

Mil-Std 810, Method 503-4, Proc. II

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +85

°C

Altitude

Standard Package, All Conditions

Sea Level through Vacuum

-

Shock

Mil-Std-810, Method 516.5, Proc. IV

20

G’s

Vibration

Mil-Std-810, Method 514.5, Fig.514.5C-3

10

G’s