Parameter

Conditions

Models

Units

Input

ALL TYPES

 

Voltage Range

Full Power

+ 23 to 30

VDC

Current

Standby / Disable

< 50

mA

Current

No Load, Max Eout

< 325

mA

Current

Full Load, Max Eout

2.5

A

AC Ripple Current

Nominal Input, Full Load

< 10

mA p-p

OUTPUT

 

1E

2E

4E

6E

10E

15E

 

Voltage Range

 Nominal Input

0 to 1,000

0 to 2,000

0 to 4,000

0 to 6,000

0 to 10,000

0 to 15,000

VDC

Nominal Input Voltage / Model

24

VDC

Power

Nominal Input, Max Eout

4

20

30

4

20

30

4

20

30

4

20

30

4

15

30

4

15

30

Watts

Current

Iout Entire Voltage Range

4

20

30

2

10

5

1

5

7.5

0.67

3.3

5

0.4

1.5

3

0.26

1

2

mA

Voltage Monitor

Normal Operating Conditions

0 to 10 ±0.5%

VDC

Current Monitor

Normal Operating Conditions

0 to 10 ±0.1%

VDC

Ripple

Full Load, Max Eout

≤ 10

PPM

Line Regulation

Nom. Input, Max Eout, Full Power

< 10ppm

VDC

Static Load Regulation

No Load to Full Load, Max Eout

< 10ppm

VDC

Stability

30 Min. warmup, per 8 hr/ per day

< 10ppm

VDC

PROGRAMMING & CONTROLS

ALL TYPES

 

Input Impedance

Nominal Input

10

MΩ

Adjust Accuracy & Adjust Linearity

10% to 100%

0.5%

%

Adjust Voltage

Differential

0 to +10

VDC

Output Voltage

T= +25°C, Initial Value

+10.00 ± 0.05%

VDC

Max Source Current

T= +25°C

1

mA

Output Impedance

Normal Operating Conditions

Buffered, low impedance, 2mA max for source/sink current

-

Enable/Disable

0 to +1 Disable, +2.5 to 15 Enable (Default = Disable)

VDC

ENVIRONMENTAL

ALL TYPES

 

Operating

Full Load, Max Eout, Case Temp.

+10 to +45

°C

Temperature Coefficient

Over the Specified Temperature

± 10

PPM/°C

Thermal Shock

Mil-Std 810, Method 504, Class 2

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +105

°C

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Altitude

Standard Package, All Conditions

Sea Level through 10,000

ft

Shock

Mil-Std-810, Method 516, Proc. 4

20

G’s

Vibration

Mil-Std-810, Method 514, Fig. 514-3

10

G’s