PARAMETER

CONDITIONS

MODELS

UNITS

Input POWER

 

12W MODELS

24W MODELS

36W MODELS

 

Voltage Range

Full Power

+12 ± 5%

+24 ± 10%

+24 ± 10%

VDC

Current

Standby ( Disabled )

< 150

< 100

< 100

mA

Current

No Load

< 0.50

< 0.50

< 0.50

A

Current

Max Load

< 2.50

< 2.30

< 3.00

A

AC Ripple Current

Nominal Input, Full Load

< 50

< 50

< 50

mA p-p

LOCAL CONTROLS: REFERENCE

ALL TYPES

 

Output Voltage

T = +25°C, Initial value

+5.1 ± 1%

VDC

Output Impedance

T = +25°C

464 ± 1%

Ω

Stability

Over full temperature range

 0.4

mV/°C

LOCAL CONTROLS: LVPS ENABLE / DISABLE

ALL TYPES

 

Power supply on

Open, or a voltage above TTL high (Isource <400uA)

+3.2 to 5

VDC

Power supply off

Grounded, or a voltage below TTL low

< 0.8 (Isink 1mA minimum)

VDC

INPUT / OUTPUT ISOLATION

15EFL

30EFL

 

Isolation Voltage

Continuous

15

30

 

kV

Leakage Current

All inputs to all outputs

< 10nA

2GΩ

nA

Leakage Capacitance

All inputs to all outputs

< 40 std, < 50 “-E”

< 40 std.

pF

ISOLATED POWER OUTPUTS

15EFL12-12W

15EFL24-24W

15EFL24-36W

 

Output #1 Power

Nominal input, max Iout

12

24

36

W

Output #1 Voltage

Nominal input voltage range

+12 ± 2%

+24 ± 2%

+24 ± 2%

VDC

Output #1 Current

Minimum to Maximum

0 to 1

0 to 1

0 to 1.5

A

Output #1 Line Regulation

Nominal input range, full load

< 0.1 %

< 0.1 %

< 0.1 %

VDC

Output #1 Load Regulation

No load to full load

< 0.25 %

< 0.30 %

< 0.40 %

VDC

Output #1 Ripple

Full load

< 2.5 %

< 1.5 %

< 1.5 %

V p-p

Output #2 & #4 Voltage

Nominal input voltage range

±15 ± 5 %

±15 ± 5 %

±15 ± 5 %

VDC

Output #2 & #4 Current

Minimum to Maximum

0 to 50

0 to 50

0 to 50

mA

Output #2 & #4 Line Regulation

Nominal input range, full load

< 0.1 %

< 0.3 %

< 0.3 %

VDC

Output #2 & #4 Load Regulation

No load to full load

< 5 %

< 1 %

< 1 %

VDC

Output #2 & #4 Ripple

Full load

< 2.5 %

< 2.5 %

< 2.5 %

V p-p

Output #3 Voltage

Nominal input voltage range

+5.1 ± 1%

+5.1 ± 1%

+5.1 ± 1%

VDC

Output #3 Current

Minimum to Maximum

500

500

500

mA

Output #3 Line Regulation

Nominal input range, full load

< 1 %

< 1 %

< 1 %

VDC

Output #3 Load Regulation

No load to full load

< 1 %

< 1 %

< 1 %

VDC

Output #3 Ripple

Full load

< 4 %

< 4 %

< 4 %

V p-p

ISOLATED CONTROLS: TTL CHANNEL “UP”

ALL TYPES

 

Local input

Source voltage, sink current

0 ≤ 0.5 (Isink 3mA minimum)
1 ≥ 2.4 (300uA or open collector)

VDC

Isolated output

Inverted & buffered TTL

1 ≥ 2.4, 0 ≤ 0.55 ± (Sources 0.8 mA, Sinks 3 mA)

VDC

Baud Rate

Duty cycle

< 15

ms

ISOLATED CONTROLS: ANALOG CHANNEL “UP”

12V MODELS

24V MODELS

 

Local input voltage

Range

0 to + 5

0 to + 10

VDC

Isolated output voltage

Range

0 to + 5

0 to + 10

VDC

Local input impedance

20.0 K

Ω

Initial offset error

< ± 2

mV

Gain error

Full scale

< ± 0.2 %

VDC

Linearity error

Full scale

< ± 0.05 %

VDC

Stability

30 min. warm-up, per 8 hrs / per day

< 0.02%

VDC

Temperature Coefficient

0 to +55 °C

< ± 10

ppm/°C

Bandwidth

Symmetric or asymmetric signal

DC to 4

Hz