PARAMETER |
CONDITIONS |
MODELS |
UNITS |
|||
|
Input POWER |
|
12W
MODELS |
24W
MODELS |
36W
MODELS |
|
|
|
|
Full Power |
+12 ± 5% |
+24 ± 10% |
+24 ± 10% |
VDC |
|
|
Current |
Standby ( Disabled ) |
< 150 |
< 100 |
< 100 |
mA |
|
|
Current |
No Load |
< 0.50 |
< 0.50
|
< 0.50
|
A |
|
|
Current |
Max Load |
< 2.50 |
< 2.30
|
< 3.00
|
A |
|
|
AC Ripple Current |
Nominal Input, Full Load |
< 50 |
< 50 |
< 50 |
mA p-p |
|
|
LOCAL CONTROLS: REFERENCE |
ALL TYPES |
|
||||
|
Output Voltage |
T = +25°C, Initial value |
+5.1 ± 1% |
VDC |
|||
|
Output Impedance |
T = +25°C |
464 ± 1% |
Ω |
|||
|
Stability |
Over full temperature range |
0.4
|
mV/°C |
|||
|
LOCAL CONTROLS: LVPS ENABLE / DISABLE |
ALL TYPES |
|
||||
|
Power supply on |
Open, or a voltage above TTL high (Isource <400uA)
|
+3.2 to 5
|
VDC |
|||
|
Power supply off |
Grounded, or a voltage below TTL low |
< 0.8 (Isink 1mA minimum)
|
VDC |
|||
|
INPUT / OUTPUT ISOLATION |
15EFL
|
30EFL
|
|
|
||
|
Isolation Voltage |
Continuous |
15
|
30
|
|
kV |
|
|
Leakage Current |
All inputs to all outputs |
< 10nA
|
|
|
nA |
|
|
Leakage Capacitance |
All inputs to all outputs |
< 40 std, < 50 “-E”
|
< 40 std.
|
|
pF |
|
|
ISOLATED POWER OUTPUTS |
15EFL12-12W |
15EFL24-24W |
15EFL24-36W |
|
||
|
Output #1 Power |
Nominal input, max Iout |
12 |
24 |
36 |
W |
|
|
Output #1 Voltage |
Nominal input voltage range |
+12 ± 2%
|
+24 ± 2%
|
+24 ± 2%
|
VDC |
|
|
Output #1 Current |
Minimum to Maximum |
0 to 1 |
0 to 1 |
0 to 1.5 |
A |
|
|
Output #1 Line Regulation |
Nominal input range, full load |
< 0.1
% |
< 0.1
% |
< 0.1
% |
VDC |
|
|
Output #1 Load Regulation |
No load to full load |
< 0.25
%
|
< 0.30
%
|
< 0.40
%
|
VDC |
|
|
Output #1 Ripple |
Full load |
< 2.5
% |
< 1.5 % |
< 1.5
% |
V p-p |
|
|
Output #2 & #4 Voltage |
Nominal input voltage range |
±15 ± 5 %
|
±15 ± 5 %
|
±15 ± 5 %
|
VDC |
|
|
Output #2 & #4 Current |
Minimum to Maximum |
0 to 50 |
0 to 50 |
0 to 50 |
mA |
|
|
Output #2 & #4 Line Regulation |
Nominal input range, full load |
< 0.1
% |
< 0.3
% |
< 0.3
% |
VDC |
|
|
Output #2 & #4 Load Regulation |
No load to full load |
< 5 % |
< 1 % |
< 1 % |
VDC |
|
|
Output #2 & #4 Ripple |
Full load |
< 2.5
% |
< 2.5
% |
< 2.5
% |
V p-p |
|
|
Output #3 Voltage |
Nominal input voltage range |
+5.1 ± 1% |
+5.1 ± 1% |
+5.1 ± 1% |
VDC |
|
|
Output #3 Current |
Minimum to Maximum |
500 |
500 |
500 |
mA |
|
|
Output #3 Line Regulation |
Nominal input range, full load |
< 1 % |
< 1 % |
< 1 % |
VDC |
|
|
Output #3 Load Regulation |
No load to full load |
< 1 % |
< 1 % |
< 1 % |
VDC |
|
|
Output #3 Ripple |
Full load |
< 4 % |
< 4 % |
< 4 % |
V p-p |
|
|
ISOLATED CONTROLS: TTL CHANNEL “UP” |
ALL TYPES |
|
||||
|
Local input |
Source voltage, sink current |
0 ≤
0.5 (Isink 3mA minimum) |
VDC |
|||
|
Isolated output |
Inverted & buffered TTL |
1 ≥ 2.4, 0 ≤ 0.55 ± (Sources 0.8 mA, Sinks 3 mA)
|
VDC |
|||
|
Baud Rate |
Duty cycle |
< 15 |
ms |
|||
|
ISOLATED CONTROLS: ANALOG CHANNEL “UP” |
12V
MODELS |
24V
MODELS |
|
|||
|
Local input voltage |
Range |
0 to + 5 |
0 to + 10 |
VDC |
||
|
Isolated output voltage |
Range |
0 to + 5 |
0 to + 10 |
VDC |
||
|
Local input impedance |
20.0 K |
Ω |
||||
|
Initial offset error |
< ± 2 |
mV |
||||
|
Gain error |
Full scale |
< ±
0.2 % |
VDC |
|||
|
Linearity error |
Full scale |
< ±
0.05 % |
VDC |
|||
|
Stability |
30 min. warm-up, per 8 hrs / per day |
<
0.02% |
VDC |
|||
|
Temperature Coefficient |
0 to +55 °C |
< ± 10 |
ppm/°C |
|||
|
Bandwidth |
Symmetric or asymmetric signal |
DC to 4 |
Hz |
|||