PARAMETERS |
SPECIFICATIONS |
UNITS |
|||||||||||||||
|
Input voltage Vin (pins 2 &
3) |
15VDC ±1.5VDC or 24VDC ±2VDC, according to type |
VDC |
|||||||||||||||
|
Input current |
Example for a 15VDC, output 6000V, 1mA model: inhibition mode: 27mA at no load & HV = 6000V 46mA, at full load < 630mA |
- |
|||||||||||||||
|
Polarity |
fixed positive or negative |
- |
|||||||||||||||
|
Output Voltage |
0 to 1000 |
0 to 2000 |
0 to 4000 |
0 to 6000 |
VDC |
||||||||||||
|
Out put Power |
1 |
2 |
4 |
6 |
1 |
2 |
4 |
6 |
1 |
2 |
4 |
6 |
1 |
2 |
4 |
6 |
W |
|
Output Current |
1 |
2 |
4 |
6 |
0.5 |
1 |
2 |
3 |
0.25 |
0.5 |
1 |
1.5 |
0.17 |
0.33 |
0.67 |
1 |
mA |
|
Programming (pins 4 & 6) |
Via external voltage source 0 to +5V ±0.1% at full scale, and input impedance = 94kΩ |
- |
|||||||||||||||
|
Max. output current Iout |
Limited to 110% of nominal current |
- |
|||||||||||||||
|
Load voltage regulation |
±0.01% of full output voltage for no load to full load |
- |
|||||||||||||||
|
Line voltage regulation |
±0.01% of full output voltage over specified input voltage range |
- |
|||||||||||||||
|
Residual ripple |
< 0.02% peak-to-peak at full load |
- |
|||||||||||||||
|
Temperature coefficient |
100 |
PPM/°C |
|||||||||||||||
|
Output HV monitoring (pin 7) {still operating in inhibition mode}
|
Analog 0 to +5V buffered output signal, accuracy ±0.2% Output impedance = 1kΩ Temperature coefficient: 50ppm/°C for ≤ 4kV units, 100ppm/°C for 6kV units |
- |
|||||||||||||||
|
Output current monitoring (pin 5) {still operating in inhibition mode} |
Analog 0 to +5V buffered output signal, accuracy ±2% Output impedance = 1kΩ Temperature coefficient: 100ppm/°C |
- |
|||||||||||||||
|
HV ON/OFF (pin 1) |
To disable (opened remote interlock) or enable (closed remote interlock) |
- |
|||||||||||||||
|
Operating temperature |
-10 to +65, Full load, Max Eout, Case Temp |
°C |
|||||||||||||||
|
Storage temperature |
-10 to +70 |
°C |
|||||||||||||||
|
Safeguards |
• Protected against reverse Vin • Soft start feature: the start is guaranteed with no overshoot • Auto inhibition if Tcase > 75°C • HV setting internally limited to 5.3V |
- |
|||||||||||||||