PARAMETER |
CONDITIONS |
MODELS |
UNITS |
||||||||||||||||||||
|
Input |
ALL tYPES |
||||||||||||||||||||||
|
|
Full Power |
+ 23 to
30 |
VDC |
||||||||||||||||||||
|
|
Derated |
+ 11 to
32 |
VDC |
||||||||||||||||||||
|
Current |
Standby / Disable |
< 40 |
mA |
||||||||||||||||||||
|
Current |
Max Load, Max Eout |
60W: 3,
125W: 6, 250W: 12 |
A |
||||||||||||||||||||
|
Current |
No Load, Max Eout |
1/8C to
1C: < 300, 2C to 6C: < 500 |
mA |
||||||||||||||||||||
|
AC Ripple Current |
Nominal Input, Full Load |
< 50 |
mA p-p |
||||||||||||||||||||
|
Output |
1/8C |
1/4C |
1/2C |
1C |
2C |
4C |
6C |
|
|||||||||||||||
|
|
Nominal Input |
0 to 125 |
0 to 250 |
0 to 500 |
0 to
1,000 |
0 to
2,000 |
0 to
4,000 |
0 to
6,000 |
VDC |
||||||||||||||
|
Power |
Nominal Input, Max Eout |
60 |
125 |
250 |
60 |
125 |
250 |
60 |
125 |
250 |
60 |
125 |
250 |
60 |
125 |
250 |
60 |
125 |
250 |
60 |
125 |
250 |
|
|
Current |
Iout, |
480 |
1000 |
2000 |
240 |
500 |
1000 |
120 |
250 |
500 |
60 |
125 |
250 |
30 |
62 |
125 |
15 |
31 |
62 |
10 |
21 |
42 |
mA |
|
Current Scale Factor |
Full Load |
400 |
833 |
1667 |
200 |
417 |
833 |
208 |
208 |
417 |
50 |
114 |
227 |
26 |
52 |
104 |
11.5 |
26 |
52 |
6.2 |
17.7 |
35 |
mA/V |
|
Voltage Monitor Scaling |
100:1 ±2%
into 10MΩ |
- |
|||||||||||||||||||||
|
Ripple |
Full Load, Max Eout,
Cload ≥0.5uF |
< 1.0 |
V p-p |
||||||||||||||||||||
|
Overshoot |
C Load, 0 Eout to Full Eout |
< 1V |
V pk |
||||||||||||||||||||
|
Rise Time |
Max Iout, Various C
Loads & Eout |
Figure A |
- |
||||||||||||||||||||
|
Storage Capacitance |
Internal |
0.90 |
0.90 |
1.80 |
0.90 |
0.90 |
1.80 |
0.43 |
0.43 |
0.85 |
0.019 |
0.019 |
0.038 |
0.019 |
0.019 |
0.038 |
0.013 |
0.013 |
0.026 |
0.013 |
0.013 |
0.026 |
uF |
|
Line Regulation |
Nom. Input, Max Eout,
Full Power |
<
0.01% |
VDC |
||||||||||||||||||||
|
Static Load Regulation |
No Load to Full Load, Max Eout |
<
0.01% |
VDC |
||||||||||||||||||||
|
Stability |
30 Min. warmup, per
8 hr/ per day |
<
0.01% / < 0.02% |
VDC |
||||||||||||||||||||
|
PROGRAMMING &
CONTROLS |
ALL TYPES |
|
|||||||||||||||||||||
|
Input Impedance |
Nominal Input |
+ Output
Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref |
MΩ |
||||||||||||||||||||
|
Adjust Resistance |
Typical Potentiometer Values |
10K to
100K (Pot across Vref. & Signal GND, Wiper to
Adjust) |
Ω |
||||||||||||||||||||
|
Adjust Logic |
0 to +5 for +Out, +5 to 0 for - Out |
+4.64 VDC
for +Output or +0.36 for -Output = Nominal Eout |
- |
||||||||||||||||||||
|
Output Voltage & Impedance |
T=+25°C |
+ 5.00VDC
± 2%, Zout = 464Ω ± 1% |
- |
||||||||||||||||||||
|
Enable/Disable |
0 to +0.5
Disable, +2.4 to 32 Enable (Default = Enable) |
VDC |
|||||||||||||||||||||
|
ENVIRONMENTAL |
ALL TYPES |
|
|||||||||||||||||||||
|
Operating |
Full Load, Max Eout,
Case Temp. |
-40 to
+65 |
°C |
||||||||||||||||||||
|
Coefficient |
Over the Specified Temperature |
±50 |
PPM/°C |
||||||||||||||||||||
|
Thermal Shock |
Mil-Std 810, Method 503-4, Proc. II |
-40 to
+65 |
°C |
||||||||||||||||||||
|
Storage |
Non-Operating, Case Temp. |
-55 to
+105 |
°C |
||||||||||||||||||||
|
Humidity |
All Conditions, Standard Package |
0 to 95%
non-condensing |
- |
||||||||||||||||||||
|
Altitude |
Standard Package, All Conditions |
Sea Level through 70,000 |
- |
||||||||||||||||||||
|
Shock |
Mil-Std-810, Method 516.5, Proc. IV |
20 |
G’s |
||||||||||||||||||||
|
Vibration |
Mil-Std-810, Method
514.5, Fig.514.5C-3 |
10 |
G’s |
||||||||||||||||||||