PARAMETER

CONDITIONS

MODELS

UNITS

Input

                           ALL tYPES

Voltage Range

Full Power

+ 23 to 30

VDC

Voltage Range

Derated Power Range

+ 11 to 32

VDC

Current

Standby / Disable

< 40

mA

Current

Max Load, Max Eout

60W: 3, 125W: 6, 250W: 12

A

Current

No Load, Max Eout

1/8C to 1C: < 300, 2C to 6C: < 500

mA

AC Ripple Current

Nominal Input, Full Load

< 50

mA p-p

Output

1/8C

1/4C

1/2C

1C

2C

4C

6C

 

Voltage Range

Nominal Input

0 to 125

0 to 250

0 to 500

0 to 1,000

0 to 2,000

0 to 4,000

0 to 6,000

VDC

Power

Nominal Input, Max Eout

60

125

250

60

125

250

60

125

250

60

125

250

60

125

250

60

125

250

60

125

250

Watts

Current

Iout, Entire Output Voltage Range

480

1000

2000

240

500

1000

120

250

500

60

125

250

30

62

125

15

31

62

10

21

42

mA

Current Scale Factor

Full Load

400

833

1667

200

417

833

208

208

417

50

114

227

26

52

104

11.5

26

52

6.2

17.7

35

mA/V

Voltage Monitor Scaling

100:1 ±2% into 10MΩ

-

Ripple

Full Load, Max Eout, Cload ≥0.5uF

< 1.0

V p-p

Overshoot

C Load, 0 Eout to Full Eout

< 1V

V pk

Rise Time

Max Iout, Various C Loads & Eout

Figure A

-

Storage Capacitance

Internal

0.90

0.90

1.80

0.90

0.90

1.80

0.43

0.43

0.85

0.019

0.019

0.038

0.019

0.019

0.038

0.013

0.013

0.026

0.013

0.013

0.026

uF

Line Regulation

Nom. Input, Max Eout, Full Power

< 0.01%

VDC

Static Load Regulation

No Load to Full Load, Max Eout

< 0.01%

VDC

Stability

30 Min. warmup, per 8 hr/ per day

< 0.01% / < 0.02%

VDC

PROGRAMMING & CONTROLS

ALL TYPES

 

Input Impedance

Nominal Input

+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref

MΩ

Adjust Resistance

Typical Potentiometer Values

10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)

Adjust Logic

0 to +5 for +Out, +5 to 0 for - Out

+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout

-

Output Voltage & Impedance

T=+25°C

+ 5.00VDC ± 2%, Zout = 464Ω ± 1%

-

Enable/Disable

0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable)

VDC

ENVIRONMENTAL

ALL TYPES

 

Operating

Full Load, Max Eout, Case Temp.

-40 to +65

°C

Coefficient

Over the Specified Temperature

±50

PPM/°C

Thermal Shock

Mil-Std 810, Method 503-4, Proc. II

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +105

°C

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Altitude

Standard Package, All Conditions

Sea Level through 70,000

-

Shock

Mil-Std-810, Method 516.5, Proc. IV

20

G’s

Vibration

Mil-Std-810, Method 514.5, Fig.514.5C-3

10

G’s