Parameter |
Conditions |
Models |
Units |
|||||||||||||||
|
Input |
ALL TYPES |
|||||||||||||||||
|
|
Full Power |
+ 23 to
30 |
VDC |
|||||||||||||||
|
|
Derated |
+ 9 to 32 |
VDC |
|||||||||||||||
|
Current |
Standby / Disable |
< 30 |
mA |
|||||||||||||||
|
Current |
No Load, Max Eout |
< 90 |
mA |
|||||||||||||||
|
Current |
Max Load, Max Eout |
20W: 950, 30W:
1425 |
mA |
|||||||||||||||
|
AC Ripple Current |
Nominal Input, Full Load |
< 80 |
mA p-p |
|||||||||||||||
|
Output |
1/16C |
1/8C |
1/4C |
1/2C |
1C |
2C |
4C |
6C |
|
|||||||||
|
|
Nominal Input |
0 to 62 |
0 to 125 |
0 to 250 |
0 to 500 |
0 to
1,000 |
0 to
2,000 |
0 to
4,000 |
0 to
6,000 |
VDC |
||||||||
|
Power |
Nominal Input, Max Eout |
20 |
30 |
20 |
30 |
20 |
30 |
20 |
30 |
20 |
30 |
20 |
30 |
20 |
30 |
20 |
30 |
|
|
Current |
Iout, |
320 |
480 |
160 |
240 |
80 |
120 |
40 |
60 |
20 |
30 |
10 |
15 |
5 |
7.5 |
3.3 |
5 |
mA |
|
Current Scale Factor |
Full Load |
TBD |
TBD |
2540 |
4210 |
1096 |
2000 |
1142 |
1667 |
307 |
476 |
159 |
259 |
94 |
112 |
51 |
86 |
mA/V |
|
Voltage Monitor Scaling |
100:1 ± 2% into 10MΩ |
- |
||||||||||||||||
|
Ripple |
Full Load, Max Eout,
Cload ≥0.5uF |
< 1.0 |
V p-p |
|||||||||||||||
|
Overshoot |
C Load, 0 Eout to Full Eout |
< 1.0 |
< 1.0 |
< 1.0 |
< 2.0 |
< 2.0 |
< 2.0 |
< 4.0 |
< 6.0 |
V pk |
||||||||
|
Rise Time |
Max Iout, Various C
Loads & Eout |
Figure A |
- |
|||||||||||||||
|
Storage Capacitance |
Internal |
TBD |
0.50 |
0.15 |
0.16 |
0.033 |
0.018 |
0.009 |
0.010 |
0.0064 |
uF |
|||||||
|
Line Regulation |
Nom. Input, Max Eout,
Full Power |
< 0.01
% |
VDC |
|||||||||||||||
|
Static Load Regulation |
No Load to Full Load, Max Eout |
<
0.01% |
VDC |
|||||||||||||||
|
Stability |
30 Min. warmup, per
8 hr/ per day |
<
0.01% / < 0.02% |
VDC |
|||||||||||||||
|
Programming &
CONTROLS |
All types |
|
||||||||||||||||
|
Input Impedance |
Nominal Input |
+ Output
Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref |
MΩ |
|||||||||||||||
|
Adjust Resistance |
Typical Potentiometer Values |
10K to
100K (Pot across Vref. & Signal GND, Wiper to
Adjust) |
Ω |
|||||||||||||||
|
Adjust Logic |
0 to +5 for +Out, +5 to 0 for - Out |
+4.64 VDC
for +Output or +0.36 for -Output = Nominal Eout |
- |
|||||||||||||||
|
Output Voltage & Impedance |
T=+25°C |
+ 5.00VDC
± 2%, Zout = 464Ω ± 1% |
- |
|||||||||||||||
|
Enable/Disable |
0 to +0.5
Disable, +2.4 to 32 Enable (Default = Enable) |
VDC |
||||||||||||||||
|
ENVIRONMENTAL |
Standard |
-25PPM Option |
|
|||||||||||||||
|
Operating |
Full Load, Max Eout,
Case Temp. |
-40 to
+65 |
+10 to
+45 |
°C |
||||||||||||||
|
Coefficient |
Over the Specified Temperature |
±50 |
±25 |
PPM/°C |
||||||||||||||
|
Thermal Shock |
Mil-Std 810, Method 503-4, Proc. II |
-40 to
+65 |
°C |
|||||||||||||||
|
Storage |
Non-Operating, Case Temp. |
-55 to
+105 |
°C |
|||||||||||||||
|
Humidity |
All Conditions, Standard Package |
0 to 95%
non-condensing |
- |
|||||||||||||||
|
Altitude |
Standard Package, All Conditions |
Sea Level
through Vacuum (Vacuum may require -P2 option, contact factory for
details)
|
- |
|||||||||||||||
|
Shock |
Mil-Std-810, Method 516.5, Proc. IV |
20
(Standard), 40 (-C Option) |
G’s |
|||||||||||||||
|
Vibration |
Mil-Std-810, Method
514.5, Fig.514.5C-3 |
10
(Standard), 20 (-C Option) |
G’s |
|||||||||||||||