PARAMETER |
CONDITIONS |
MODELS |
UNITS |
|||||
|
Input |
AC INPUT |
DC INPUT |
|
|||||
|
Voltage Range |
Full Power |
90-260 VAC |
22-26 VDC |
- |
||||
|
Output |
AC INPUT |
DC INPUT |
|
|||||
|
Voltage Range |
Nominal Input |
0 to 10,000 |
0 to 20,000 |
0 to 30,000 |
0 to 10,000 |
0 to 20,000 |
0 to 30,000 |
VDC |
|
Power |
Nominal Input, Max Eout |
0 to 30 |
0 to 30 |
Watts |
||||
|
Current |
Iout Entire Output Voltage Range |
3.0 |
1.5 |
1.0 |
30 |
1.5 |
1.0 |
mA |
|
Ripple |
Full Load, Max Eout |
<0.01 |
<0.3 |
%V p-p |
||||
|
Line Regulation |
Nom. Input, Max Eout, Full Power |
TBD |
<0.3% |
VDC |
||||
|
Load Regulation |
No Load to Full Load, Max Eout |
<0.01% |
<0.01% |
VDC |
||||
|
Stability |
30 Min. warmup, per 8 hr/ per day |
<0.1% |
<0.1% |
VDC |
||||
|
PROGRAMMING & CONTROLS |
ALL TYPES |
|
||||||
|
HV ON/OFF Controls |
Front panel switch |
- |
||||||
|
Environmental |
AC INPUT |
DC INPUT |
|
|||||
|
Coefficient |
Over the Specified Temperature |
100 |
200 |
PPM/°C |
||||
|
Storage Temperature |
Non-Operating, Case Temp. |
-20 to +60 |
°C |
|||||
|
Operating Temperature |
Full Load, Max Eout, Case Temp. |
0 to +40 |
°C |
|||||
|
Humidity |
All Conditions, Standard Package |
0 to 90% non-condensing |
- |
|||||