Parameter

Conditions

Models

Units

Input

12V

24V

 

Voltage Range

Full Power

+ 11 to 16

+ 23 to 30

VDC

Voltage Range

Derated Power Range

+ 9 to 32

+ 9 to 32

VDC

Current

Standby / Disable

< 30

< 30

mA

Current

No Load, Max Eout

< 100

< 90

mA

Current

Max Load, Max Eout

~ 400

~ 1350

mA

AC Ripple Current

Nominal Input, Full Load

< 80

< 80

mA p-p

Output

1/16AA

1/8AA

1/4AA

1/2AA

1AA

2AA

4AA

6AA

 

Voltage Range

Nominal Input

0 to 62

0 to 125

0 to 250

0 to 500

0 to 1,000

0 to 2,000

0 to 4,000

0 to 6,000

VDC

Nominal Input Voltage / Model

12

24

24

12

24

24

12

24

24

12

24

24

12

24

24

12

24

24

12

24

24

12

24

24

VDC

Power

Nominal Input, Max Eout

4

20

30

4

20

30

4

20

30

4

20

30

4

20

30

4

20

30

4

20

30

4

20

30

Watts

Current

Iout Entire Output Voltage Range

64

320

480

32

160

240

16

80

120

8

40

60

4

20

30

2

10

15

1

5

7.5

0.67

3.3

5

mA

Current Scale Factor

Full Load

42.67

969.7

960

11.64

237

258

3.27

70.48

72.7

.79

17.78

17.65

.37

4.60

4.62

.192

1.52

1.52

.090

.752

.76

.067

.490

.50

mA/V

Voltage Monitor Scaling

10:1 ± 2% into 10MΩ

100:1 ± 2% into 10MΩ

-

Ripple

Full Load, Max Eout

0.03

0.06

0.15

0.03

0.038

0.038

0.023

0.04

0.05

0.01

0.01

0.011

0.026

0.048

0.073

0.01

0.011

0.046

0.042

0.050

0.070

0.035

0.024

0.046

%V p-p

Dynamic Load Regulation

½ to Full Load, Max Eout per .1mA

<.12

<.12

<.20

<.50

<1.0

<2.0

<4.0

<6.0

V pk

Line Regulation

Nom. Input, Max Eout, Full Power

< 0.01 %

VDC

Static Load Regulation

No Load to Full Load, Max Eout

< 0.01%

VDC

Stability

30 Min. warmup, per 8 hr/ per day

< 0.01%  /  < 0.02%

VDC

PROGRAMMING & ConTROLS

ALL TYPES

 

Input Impedance

Nominal Input

+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref

MΩ

Adjust Resistance

Typical Potentiometer Values

10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)

Adjust Logic

0 to +5 for +Out, +5 to 0 for - Out

+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout

-

Output Voltage & Impedance

T=+25°C

+ 5.00VDC ± 2%, Zout = 464Ω ± 1%

-

Enable/Disable

0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable)

VDC

EnVIRONMENTAL

ALL TYPES

 

Operating

Full Load, Max Eout, Case Temp.

-40 to +65

°C

Coefficient

Over the Specified Temperature

±50

PPM/°C

Thermal Shock

Mil-Std 810, Method 503-4, Proc. II

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +105

°C

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Altitude

Standard Package, All Conditions

Sea Level through Vacuum

-

Shock

Mil-Std-810, Method 516.5, Proc. IV

20

G’s

Vibration

Mil-Std-810, Method 514.5, Fig.514.5C-3

10

G’s