Parameter

Conditions

MODELS

Units

Input

ALL TYPES

 

Voltage Range

Full Power

+ 23 to 30

VDC

Voltage Range

Derated Power Range

+ 11 to 30

VDC

Current

Standby / Disable

< 40

mA

Current

No Load, Max Eout

8C to 15C < 500, 20C to 25C < 600

mA

Current

Max Load, Max Eout

60W: 3, 125W: 6

A

AC Ripple Current

Nominal Input, Full Load

< 50

mA p-p

Output

8C

10C

12C

15C

20C

25C

30C

 

Voltage Range

Nominal Input

0 to 8,000

0 to 10,000

0 to 12,000

0 to 15,000

0 to 20,000

0 to 25,000

0 to 30,000

VDC

Power

Nominal Input, Max Eout

60

125

60

125

60

125

60

125

60

125

60

125

60

125

Watts

Current

Iout, Entire Output Voltage Range

7.5

15.5

6

12.5

5

10.5

4

8.3

3

6.25

2.4

5

2

4.17

mA

Current Scale Factor

Full Load

4.7

14.2

4.1

10.9

4.0

7.4

4.0

7.5

.65

.653

.65

.650

.65

.642

mA/V

Voltage Monitor Scaling

1000:1 ± 2% into 10MΩ

-

Internal Capacitance

Capacitance / 95% Decay (50Meg Load)

2800/700

2000/575

2000/650

2000/650

1600/240

1600/240

1600/240

pF/mS

 

Ripple

Full Load, Max Eout

< 1.0 (Cload ≥ 0.05uF)

< 1.0 (Cload ≥ 0.01uF)

V p-p

Rise Time

Max Iout, Various C Loads & Eout

Figure A

-

Storage Capacitance

Internal

2800

2800

2000

2000

2000

2000

2000

2000

782

1182

710

1110

710

1110

pF

Overshoot

C Load, 0 Eout to Full Eout

< 0.1 %

V pk

Line Regulation

Nom. Input, Max Eout, Full Power

< 0.01 %

VDC

Static Load Regulation

No Load to Full Load, Max Eout

< 0.01%

VDC

Stability

30 Min. warmup, per 8 hr/ per day

< 0.01%  /  < 0.02%

VDC

PROGRAMMING & CONTROLS

ALL TYPES

 

Input Impedance

Nominal Input

+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref

MΩ

Adjust Resistance

Typical Potentiometer Values

10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)

Adjust Logic

0 to +5 for +Out, +5 to 0 for - Out

+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout

-

Output Voltage & Impedance

 

T=+25°C

+ 5.00VDC ± 2%, Zout = 464Ω ± 1%

-

Enable/Disable

0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable)

VDC

ENVIRONMENTAL

ALL TYPES

 

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Coefficient

Over the Specified Temperature

± 50

PPM/°C

Thermal Shock

Mil-Std-810, Method 503-4, Proc. II

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +105

°C

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Altitude

Standard Package, All Conditions

Sea Level through 70,000

ft

Shock

Mil-Std-810, Method 516.5, Proc. IV

20

G’s

Vibration

Mil-Std-810, Method 514.5, Fig.514.5C-3

10

G’s