Parameter

Conditions

Models

Units

Input

12V

24V

 

Voltage Range

Full Power

+ 11 to 16

+ 23 to 30

VDC

Voltage Range

Derated Power Range

+ 9 to 32

+ 9 to 32

VDC

Current

Standby / Disable

< 30

< 30

mA

Current

No Load, Max Eout

30A < 0.25, 35A < 0.35, 40A < 0.38

30A < 0.30, 35A < 0.20, 40A < 0.38

A

Current

Max Load, Max Eout

~ 800

~1800

mA

AC Ripple Current

Nominal Input, Full Load

< 80

< 80

mA p-p

Output

30A

35A

40A

 

Voltage Range

Nominal Input

0 to 30,000

0 to 35,000

0 to 40,000

VDC

Nominal Input Voltage / Model

12

24

24

12

24

24

12

24

24

VDC

Power

Nominal Input, Max Eout

4

15

30

4

15

30

4

15

30

Watts

Current

Iout Entire Output Voltage Range

0.13

0.50

1.0

0.11

0.42

0.86

0.10

0.37

0.75

mA

Current Scale Factor

Full Load

.140

.173

.181

.158

.179

.184

.077

.089

.092

mA/V

Voltage Monitor Scaling

1000:1 ± 2% into 10MΩ

-

Ripple

Full Load, Max Eout, 300pF bypass Cap.

0.021

0.039

0.048

0.016

0.034

0.040

0.030

0.060

0.064

%V p-p

Ripple with -F-M Option

Full Load, Max Eout, 300pF bypass Cap.

0.025

0.028

0.058

0.025

0.040

0.075

0.007

0.025

0.053

%V p-p

Dynamic Load Regulation

½ to Full Load, Max Eout per 0.1mA

<10.0

<10.0

<10.0

<10.0

<10.0

<10.0

<10.0

<10.0

<10.0

V pk

Line Regulation

Nom. Input, Max Eout, Full Power

< 0.01 %

VDC

Static Load Regulation

No Load to Full Load, Max Eout

< 0.01%

VDC

Stability

30 Min. warmup, per 8 hr/ per day

< 0.01%  /  < 0.02%

VDC

PROGRAMMING & CONTROLS

ALL TYPES

 

Input Impedance

Nominal Input

+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref

MΩ

Adjust Resistance

Typical Potentiometer Values

10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)

Adjust Logic

0 to +5 for +Out, +5 to 0 for - Out

+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout

-

Output Voltage & Impedance

T=+25°C

+ 5.00VDC ± 2%, Zout = 464Ω ± 1%

-

Enable/Disable

0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable)

VDC

ENVIRONMENTAL

Standard

-25PPM

 

Operating

Full Load, Max Eout, Case Temp.

-40 to +65

+10 to +45

°C

Coefficient

Over the Specified Temperature

± 50

± 25

PPM/°C

Thermal Shock

Mil-Std 810, Method 503-4, Proc. II

-40 to +65

°C

Storage

Non-Operating, Case Temp.

-55 to +105

°C

 

Humidity

All Conditions, Standard Package

0 to 95% non-condensing

-

Altitude

Standard Package, All Conditions

Sea Level through Vacuum (Vacuum may require -P2 option, contact factory for details.)

-

Shock

Mil-Std-810, Method 516.5, Proc. IV

20 (Standard), 40 (-C Option)

G’s

Vibration

Mil-Std-810, Method 514.5, Fig.514.5C-3

10 (Standard), 20 (-C Option)

G’s