Pin Number |
Signal Name |
Function |
Parameter |
1 |
Remote Enable A |
TTL high to enable, low to disable
Channel A |
Default is off via internal pull down |
2 |
Remote Voltage Adj A |
Voltage Programming for Channel A |
0V to 4.64V = 0V to 100% Vmax. (5V = 108% Vo) |
3 |
Voltage Monitor A |
Voltage Monitor for Channel A |
0V to 4.64V = 0Vo to 100% Vo (5V = 108% Vo) |
4 |
Remote Current Adj A |
Current Programming for Channel A |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
5 |
Current Monitor A |
Current Monitor for Channel A |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
6 |
Reference Voltage A |
5V precision voltage reference returned
to signal ground A |
|
7 |
Signal Ground A |
Signal Ground for Channel A |
|
8 |
Remote Enable B |
TTL high to enable, low to disable
Channel B |
Default is off via internal pull down |
9 |
Remote Voltage Adj B |
Voltage Programming for Channel B |
0V to 4.64V = 0V to 100% Vmax. (5V = 108% Vo) |
10 |
Voltage Monitor B |
Voltage Monitor for Channel B |
0V to 4.64V = 0Vo to 100% Vo (5V = 108% Vo) |
11 |
Remote Current Adj B |
Current Programming for Channel B |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
12 |
Current Monitor B |
Current Monitor for Channel B |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
13 |
Reference Voltage B |
5V precision voltage reference returned
to signal ground B |
|
14 |
Signal Ground B |
Signal Ground for Channel B |
|
15 |
Remote Enable C |
TTL high to enable, low to disable
Channel C |
Default is off via internal pull down |
16 |
Remote Voltage Adj C |
Voltage Programming for Channel C |
0V to 4.64V = 0V to 100% Vmax. (5V = 108% Vo) |
17 |
Voltage Monitor C |
Voltage Monitor for Channel C |
0V to 4.64V = 0Vo to 100% Vo (5V = 108% Vo) |
18 |
Remote Current Adj C |
Current Programming for Channel C |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
19 |
Current Monitor C |
Current Monitor for Channel C |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
20 |
Reference Voltage C |
5V precision voltage reference returned
to signal ground C |
|
21 |
Signal Ground C |
Signal Ground for Channel C |
|
22 |
Remote Enable D |
TTL high to enable, low to disable
Channel D |
Default is off via internal pull down |
23 |
Remote Voltage Adj D |
Voltage Programming for Channel D |
0V to 4.64V = 0V to 100% Vmax. (5V = 108% Vo) |
24 |
Voltage Monitor D |
Voltage Monitor for Channel D |
0V to 4.64V = 0Vo to 100% Vo (5V = 108% Vo) |
25 |
Remote Current Adj D |
Current Programming for Channel D |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
26 |
Current Monitor D |
Current Monitor for Channel D |
0V to 4.64V = 0A to 100% Io (5V = 108% Io) |
27 |
Reference Voltage D |
5V precision voltage reference returned
to signal ground D |
|
28 |
Signal Ground D |
Signal Ground for Channel D |
|
29 |
Not Used |
|
|
30 |
Not Used |
|
|
31 |
Not Used |
|
|
32 |
Not Used |
|
|
33 |
Not Used |
|
|
34 |
Not Used |
|
|
35 |
+15V, 100mA power |
Power supply for low power external circuitry |
|
36 |
Power Ground |
Return for +15V |
|
37 |
Global Disable |
TTL signal disables all Channels, low to enable,
high to disable. |
Default is ENABLE. |