This site and contents herein are ©1998-2007, UltraVolt, Inc.



Products

High Power "C" Series High Voltage Power Supply

PDF version is also available
Currently viewing page: 1 Jump to page: 1 2 3 4

Click here to request more information or to get a quote

HIGH POWER “C” SERIES

HIGH VOLTAGE POWER SUPPLY

Typical Characteristics:

Parameter Conditions
Models
Units
Input:
All Types
Voltage Range Full Power
+ 23 to 30
VDC
Voltage Range Derated Power Range
+ 11 to 32
VDC
Current Standby / Disable
< 40
mA
Current Max Load, Extended Input Voltage
Figures A & B
Graph
AC Ripple Current Nominal Input, Full Load
< 50
mA p-p
Output:
1/8C
1/4C
1/2C
1C
2C
4C
6C
Voltage Range Nominal Input
0 to 125
0 to 250
0 to 500
0 to 1,000
0 to 2,000
0 to 4,000
0 to 6,000
VDC
Power Nominal Input, Max Eout
60
125
250
60
125
250
60
125
250
60
125
250
60
125
250
60
125
250
60
125
250
Watts
Current Iout, Entire Output Voltage Range
480
1000
2000
240
500
1000
120
250
500
60
125
250
30
62
125
15
31
62
10
21
42
mA
Ripple Full Load, Max Eout, Cload =0.5uF
< 1.0
< 1.0
< 1.0
< 1.0
< 1.0
< 1.0
< 1.0
V p-p
Overshoot C Load, 0 Eout to Full Eout
< 1V
< 1V
< 1V
< 1V
< 1V
< 1V
< 1V
V pk
Voltage Derating Max Iout, Extended Input Voltage
Figure C
Graph
Rise Time Max Iout, Various C Loads & Eouts
Figures D & F
Table
Line Regulation Nom. Input, Max Eout, Full Power
< 0.01%
VDC
Static Load Regulation No Load to Full Load, Max Eout
< 0.01%
VDC
Stability 30 Min. warmup, per 8 hr/ per day
< 0.01% / < 0.02%
VDC
Output Voltage Monitor:
All Types
Voltage Full Eout Range, Full Iout Range
10.00
V per kV
Proportionality Full Eout Range, Full Iout Range
± 0.08%
V per kV
Remote Programming:
All Types
Input Impedance Nominal Input
+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref
Adjust Resistance Typical Potentiometer Values
10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)
Ω
Adjust Linearity 0% to 100%
Figure E
Graph
Adjust Voltage Referenced to signal ground
Figure E (0 to +5 VDC)
Graph
Adjust Logic 0 to +5 for +Out, +5 to 0 for -Out
+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout
Reference:
All Types
Output Voltage T=+25°C , Initial Value
+ 5.00 ± 2%
VDC
Output Impedance T=+25°C
464 ± 1%
Ω
Stability Over Full Temperature Range
See “A” Series Datasheet Figure F
Graph
Enable:
All Types
Power Supply On Floated, or voltage ≥ TTL High
+2.4 to 32
VDC
Power Supply Off Grounded, or voltage ≤ TTL Low
0 to + 0.7 ± 0.2 (Isink 1mA minimum)
VDC
Temperature & Humidity:
All Types
Humidity All Conditions, Standard Package  
0 to 95% non-condensing
Operating Full Load, Max Eout, Case Temp.
-40 to +65
°C
Storage Non-Operating, Case Temp.
-55 to +105
°C
Coefficient Over the Specified Temperature
± 50
PPM / °C
Thermal Shock Mil-Std 810, Method 503-4, Proc. II
-40 to +65
°C
Altitude:
All Types
All Conditions Standard Package
Sea Level through Vacuum
Shock & Vibration:
All Types
Shock Mil-Std-810, Method 516.5, Proc. IV
20
G's
Vibration Mil-Std-810, Method 514.5, Fig. 514.5C-3
10
G's
Packaging:
60W/125W
250W
Material Outer construction
Aluminum Alloy 5052-H32, Finish: Mil-C-5541 Class 1A
Aluminum Alloy 5052-H32, Finish: Mil-C-5541 Class 1A
Length Not including pins or mounting pts
4.00 ± 0.025 (101.6±.6)
8.00 ± 0.025 (203.2±.6)
In (mm)
Width Not including pins or mounting pts
4.50 ± 0.025 (114.3±.6)
4.50 ± 0.025 (114.3±.6)
In (mm)
Height Not including pins or mounting pts
1.075 ± 0.025 (27.3±.6)
1.075 ± 0.025 (27.3±.6)
In (mm)
Volume Not including pins or mounting pts
19.35 (317)
38.7 (634)
In3 (cc)
Weight Overall
1.4 (.64)
2.6 (1.18)
Lbs (kg)

Specifications subject to change without notice

previous page next page

© 2003-2007 UltraVolt, Inc.
specifications subject to change without notice


UltraVolt, Inc.
1800 Ocean Ave. Frnt
Ronkonkoma, NY 11779
1-800-9HV-POWER
1-800-948-7693
631-471-4444
Fax: 631-471-4696
E-mail: csd@ultravolt.com