Products

"FL" Series Floating Hot Deck with Isolated Digital and Analog I/O

PDF version is also available
Currently viewing page: 1 Jump to page: 1 2 3 4

Click here to request more information or to get a quote

“FL” SERIES

FLOATING HOT DECK LVPS WITH ISOLATED DIGITAL AND ANALOG I/O

Typical Characteristics:

Parameter

Conditions

Models

Units

Input Power:

 

12V Models

24V Models

 

Voltage Range

Full Power

+12 ± 5%

+24 ± 4%

VDC

Voltage Range

Derated Power Range

+10.8 to +16

+21.6 to +30

VDC

Current

Standby ( Disabled )

< 90

< 50

mA

Current

No Load

< 0.15

< 0.15

A

Current

Max Load

< 1.60

< 1.40

A

AC Ripple Current

Nominal Input, Full Load

< 80

< 100

mA p-p

Local Controls: Reference

All Types

 

Output Voltage

T = +25°C, Initial value

+ 5.00 ± 2 %

VDC

Output Impedance

T = +25°C

464 ± 1%

Ω

Stability

Over full temperature range

See "A" Series Data Sheet, Figure F

Graph

Local Controls: LVPS Enable / Disable

All Types

 

Power supply on

Open, or a voltage above TTL high

+2.4 to 32

VDC

Power supply off

Grounded, or a voltage below TTL low

0 to + 0.7 ± 0.2 (Isink 1mA minimum)

VDC

Input / Output Isolation:

12V Models

24V Models

 

Isolation Voltage

Continuous

15

15

kV

Leakage Current

All inputs to all outputs

< 10 std, < 100 “-E”

< 10 std, < 100 “-E”

nA

Leakage Capacitance

All inputs to all outputs

< 40 std, < 50 "-E"

< 50 std or "-E"

pF

Isolated Power Outputs:

15FL12-12W

15FL24-24W

 

Output #1 Power

Nominal input, max Iout

12

24

W

Output #1 Voltage

Nominal input voltage range

+12 ± 5%

+24 ± 5%

VDC

Output #1 Current

Minimum to Maximum

0 to 1

0 to 1

A

Output #1 Line Regulation

Nominal input range, full load

< 0.1 %

< 0.3 %

VDC

Output #1 Load Regulation

No load to full load

< 0.5 %

< 0.25 %

VDC

Output #1 Ripple

Full load

< 2 %

< 1%

V p-p

Output #2 Voltage

Nominal input voltage range

-12 ± 10%

-12 ± 5%

VDC

Output #2 Current

Minimum > Maximum

0 to 10

0 to 10

mA

Output #2 Line Regulation

Nominal input range, full load

< 0.1 %

< 0.3 %

VDC

Output #2 Load Regulation

No load to full load

< 5 %

< 1 %

VDC

Output #2 Ripple

Full load

< 2 %

< 1 %

V p-p

Output #3 Voltage

Nominal input voltage range

+5.6 ± 5%

+5.6 ± 5%

VDC

Output #3 Current

Minimum > Maximum

0 to 10

0 to 10

mA

Output #3 Line Regulation

Nominal input range, full load

< 1 %

< 1 %

VDC

Output #3 Load Regulation

No load to full load

< 1 %

< 1 %

VDC

Output #3 Ripple

Full load

< 1 %

< 1 %

V p-p

Isolated Controls: TTL Channel "UP"

All Types with "-I/O" option

 

Local input

Source voltage, sink current

0 = <0.5 (Isink 3mA minimum)

       1 = >2.4 (300uA or open collector)

VDC

Isolated output

Inverted & buffered TTL

1 ³ 2.4, 0 £ 0.4 ± (Sources 0.8 mA, Sinks 13 mA)

VDC

Baud Rate

Varying duty cycle

DC to >300

kHz

Isolated Controls: Analog Channel "UP"

All Types with "-I/O" option

 

Local input voltage

Range

0 to + 5

VDC

Local input impedance

23.2 K

Ω

Isolated output voltage

Range

0 to + 5

VDC

Isolated output impedance

1.5K Ω ± 1%

Ω

Initial offset error

 

< ± 2

mV

Gain error

Full scale

< ± 2 %

VDC

Linearity error

0 to full scale

< ± 1 %

VDC

Stability

30 min. warm-up, per 8 hrs / per day

< 0.01% / < 0.02%

VDC

Temperature Coefficient

0 to +55 °C

< ± 50

ppm/°C

Bandwidth

Symmetric or asymmetric signal

DC to 30 (-3dB point is 47 Hz)

Hz

Specifications subject to change without notice

previous page next page

© 2003-2007 UltraVolt, Inc.
specifications subject to change without notice


UltraVolt, Inc.
1800 Ocean Ave. Frnt
Ronkonkoma, NY 11779
1-800-9HV-POWER
1-800-948-7693
631-471-4444
Fax: 631-471-4696
E-mail: csd@ultravolt.com