Parameter |
Conditions |
Models |
Units |
Input Power: |
|
12V Models |
24V Models |
|
Voltage Range |
Full Power |
+12
± 5% |
+24
± 4% |
VDC |
Voltage Range |
Derated Power Range |
+10.8
to +16 |
+21.6
to +30 |
VDC |
Current |
Standby ( Disabled ) |
<
90 |
<
50 |
mA |
Current |
No Load |
<
0.15 |
<
0.15 |
A |
Current |
Max Load |
<
1.60 |
<
1.40 |
A |
AC Ripple Current |
Nominal Input, Full Load |
<
80 |
<
100 |
mA
p-p |
Local Controls: Reference |
All Types |
|
Output Voltage |
T = +25°C, Initial value |
+
5.00 ± 2 % |
VDC |
Output Impedance |
T = +25°C |
464
± 1% |
Ω |
Stability |
Over full temperature range |
See
"A" Series Data Sheet, Figure F |
Graph |
Local Controls: LVPS Enable / Disable |
All Types |
|
Power supply on |
Open, or a voltage above TTL high |
+2.4
to 32 |
VDC |
Power supply off |
Grounded, or a voltage below TTL low |
0
to + 0.7 ± 0.2 (Isink 1mA minimum) |
VDC |
Input / Output Isolation: |
12V Models |
24V Models |
|
Isolation Voltage |
Continuous |
15 |
15 |
kV |
Leakage Current |
All inputs to all outputs |
<
10 std, < 100 “-E” |
<
10 std, < 100 “-E” |
nA |
Leakage Capacitance |
All inputs to all outputs |
<
40 std, < 50 "-E" |
<
50 std or "-E" |
pF |
Isolated Power Outputs: |
15FL12-12W |
15FL24-24W |
|
Output #1 Power |
Nominal input, max Iout |
12 |
24 |
W |
Output #1 Voltage |
Nominal input voltage range |
+12
± 5% |
+24
± 5% |
VDC |
Output #1 Current |
Minimum to Maximum |
0
to 1 |
0
to 1 |
A |
Output #1 Line Regulation |
Nominal input range, full load |
<
0.1 % |
<
0.3 % |
VDC |
Output #1 Load Regulation |
No load to full load |
<
0.5 % |
<
0.25 % |
VDC |
Output #1 Ripple |
Full load |
<
2 % |
<
1% |
V
p-p |
Output #2 Voltage |
Nominal input voltage range |
-12
± 10% |
-12
± 5% |
VDC |
Output #2 Current |
Minimum > Maximum |
0
to 10 |
0
to 10 |
mA |
Output #2 Line Regulation |
Nominal input range, full load |
<
0.1 % |
<
0.3 % |
VDC |
Output #2 Load Regulation |
No load to full load |
<
5 % |
<
1 % |
VDC |
Output #2 Ripple |
Full load |
<
2 % |
<
1 % |
V
p-p |
Output #3 Voltage |
Nominal input voltage range |
+5.6
± 5% |
+5.6
± 5% |
VDC |
Output #3 Current |
Minimum > Maximum |
0
to 10 |
0
to 10 |
mA |
Output #3 Line Regulation |
Nominal input range, full load |
<
1 % |
<
1 % |
VDC |
Output #3 Load Regulation |
No load to full load |
<
1 % |
<
1 % |
VDC |
Output #3 Ripple |
Full load |
<
1 % |
<
1 % |
V
p-p |
Isolated Controls: TTL Channel "UP" |
All Types with
"-I/O" option |
|
Local input |
Source voltage, sink current |
0
= <0.5 (Isink 3mA minimum)
1 = >2.4 (300uA or open collector) |
VDC |
Isolated output |
Inverted & buffered TTL |
1 ³ 2.4, 0 £ 0.4 ± (Sources
0.8 mA, Sinks 13 mA) |
VDC |
Baud Rate |
Varying duty cycle |
DC
to >300 |
kHz |
Isolated Controls: Analog Channel "UP" |
All Types with
"-I/O" option |
|
Local input voltage |
Range |
0
to + 5 |
VDC |
Local input impedance |
23.2
K |
Ω |
Isolated output voltage |
Range |
0
to + 5 |
VDC |
Isolated output impedance |
1.5K Ω ± 1% |
Ω |
Initial offset error |
|
<
± 2 |
mV |
Gain error |
Full scale |
<
± 2 % |
VDC |
Linearity error |
0 to full scale |
<
± 1 % |
VDC |
Stability |
30 min. warm-up, per 8 hrs / per day |
<
0.01% / < 0.02% |
VDC |
Temperature Coefficient |
0 to +55 °C |
<
± 50 |
ppm/°C |
Bandwidth |
Symmetric or asymmetric signal |
DC
to 30 (-3dB point is 47 Hz) |
Hz |