Parameter |
Conditions |
|
Units |
Input: |
All
Types |
|
|
Voltage Range |
Full
Power |
+ 23 to 30 |
VDC |
|
Voltage Range |
Derated
Power Range |
+ 11 to 30 |
VDC |
|
Current |
Standby
/ Disable |
< 40 |
mA |
|
Current |
No
Load, Max Eout |
8C to 15C < 500, 20C
to 25C <600 |
mA |
|
Current |
Max
Load, Extended Input Voltage |
See High Power
“C” Datasheet Figure B |
Graph |
|
AC
Ripple Current |
Nominal
Input, Full Load |
< 50 |
mA p-p |
|
Output:
|
8C |
10C |
12C |
15C |
20C |
25C |
30C |
|
|
Voltage Range |
Nominal Input |
0 to 8,000 |
0 to 10,000 |
0 to 12,000 |
0 to 15,000 |
0 to 20,000 |
0 to 25,000 |
0 to 30,000 |
VDC |
|
Power |
Nominal Input, Max Eout |
60 |
125 |
60 |
125 |
60 |
125 |
60 |
125 |
60 |
125 |
60 |
125 |
60 |
125 |
Watts |
|
Current |
Iout,
Entire Output Voltage Range |
7.5 |
15.5 |
6 |
12.5 |
5 |
10.5 |
4 |
8.3 |
3 |
6.25 |
2.4 |
5 |
2 |
4.17 |
mA |
|
Internal Capacitance |
Capacitance / 95% Decay (50Meg Load) |
2800 / 700 |
2000 / 575 |
2000 / 650 |
2000 / 650 |
1600 / 240 |
1600 / 240 |
1600 / 240 |
pF / mS |
|
Ripple |
Full Load, Max Eout |
< 1.0 (Cload ≥0.05uF) |
< 1.0 (Cload ≥0.01uF) |
V p-p |
|
Overshoot |
C Load, 0 Eout to Full Eout |
< 0.1% |
V pk |
|
Voltage Derating |
Max Iout, Extended Input Voltage |
Figure C |
Graph |
|
Rise Time |
Max Iout, Various C Loads & Eout |
Figures D & F |
Table |
|
Line Regulation |
Nom. Input, Max Eout, Full Power |
< 0.01 % |
VDC |
|
Static Load Regulation |
No Load to Full Load, Max Eout |
< 0.01% |
VDC |
|
Stability |
30 Min. warmup, per 8 hr/ per day |
< 0.01% / <
0.02% |
VDC |
Output Voltage
Monitor: |
All
Types |
|
|
Voltage |
Full
Eout Range, Full Iout Range |
1.00 (1GΩ / 1.1MΩ Divider with 10 MΩ
meter) |
V per kV |
|
Proportionality |
Full
Eout Range, Full Iout Range |
± 0.08% |
V per kV |
Remote Programming: |
All
Types |
|
|
Input Impedance |
Nominal Input |
+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref |
MΩ |
|
Adjust Resistance |
Typical Potentiometer Values |
10K to 100K (Pot across Vref.
& Signal GND, Wiper to Adjust) |
Ω |
|
Adjust Linearity |
0% to 100% |
Figure E |
Graph |
|
Adjust Voltage |
Referenced to signal ground |
Figure E (0 to +5 VDC) |
Graph |
|
Adjust Logic |
0 to +5 for +Out, +5 to 0 for -Out |
+4.64 VDC for +Output or
+0.36 for -Output = Nominal Eout |
|
Reference: |
All
Types |
|
|
Output Voltage |
T=+25°C, Initial Value |
+ 5.00 ± 2% (±
0.05% optional) |
VDC |
|
Output Impedance |
T=+25°C |
464 ± 1% |
Ω |
|
Stability |
Over Full Temperature Range |
See “A” Series Datasheet
Figure F (± 5 PPM optional) |
Graph |
Enable: |
All
Types |
|
|
Power Supply On |
Floated, or voltage ≥ TTL High |
+2.4 to 32 |
VDC |
|
Power Supply Off |
Grounded, or voltage ≤ TTL Low |
0 to + 0.7 ± 0.2 (Isink 1mA minimum) |
VDC |
Temperature & Humidity: |
All
Types |
|
|
Humidity |
All Conditions, Standard Package |
0 to 95% non-condensing |
|
Operating |
Full Load, Max Eout, Case Temp. |
-40 to +65 |
°C |
|
Storage |
Non-Operating, Case Temp. |
-55 to +105 |
°C |
|
Coefficient |
Over the Specified Temperature |
± 50 |
PPM/°C |
|
Thermal Shock |
Mil-Std-810, Method 503-4, Proc. II |
-40 to +65 |
°C |
Altitude: |
All
Types |
|
|
All Conditions |
Standard Package |
Sea Level through 70,000 |
FT |
Shock &
Vibration: |
All
Types |
|
|
Shock |
Mil-Std-810, Method 516.5, Proc. IV |
20 |
G's |
|
Vibration |
Mil-Std-810, Method 514.5, Fig. 514.5C-3 |
10 |
G's |
Packaging: |
All
Types |
|
|
Material |
Outer construction |
Aluminum Alloy 5052-H32,
Finish: MIL-C-5541 Class 1A |
|
|
Length |
Not including pins or mounting pts |
8.00 ± 0.025 (203.2 ± .6) |
In (mm) |
|
Width |
Not including pins or mounting pts |
4.50 ± 0.025 (114.3 ± .6) |
In (mm) |
|
Height |
Not including pins or mounting pts |
1.075 ± 0.025 (27.3 ± .6) |
In (mm) |
|
Volume |
Not including pins or mounting pts |
38.7 (634) |
In³ (cc) |
|
Weight |
Overall |
2.6 (1.18) |
Lbs (kg) |