Parameter |
Conditions |
Models |
Units |
|
Input: |
|
12V |
24V |
|
|
Voltage
Range |
Full Power |
+ 11 to 16 |
+ 23 to 30 |
VDC |
|
Voltage
Range |
Derated Power
Range |
+ 9 to 32 |
+ 9 to 32 |
VDC |
|
Current |
Standby / Disable |
<
30 |
<
30 |
mA |
|
Current |
No Load, Max Eout |
30A<0.25,
35A<0.35, 40A< 0.38 |
30A< 0.30, 35A<0.20, 40A<0.38 |
A |
|
Current |
Max Load, Extended Input Voltage |
Figures
A & B |
Figures
A & B |
Graph |
|
AC Ripple Current |
Nominal Input, Full Load |
<
80 |
<
80 |
mA
p-p |
|
Output: |
|
30A |
35A |
40A |
|
|
Voltage
Range |
Nominal Input |
0
to 30,000 |
0
to 35,000 |
0
to 40,000 |
VDC |
|
Nominal Input Voltage / Model |
12 |
24 |
24 |
12 |
24 |
24 |
12 |
24 |
24 |
VDC |
|
Power |
Nominal Input, Max Eout |
4 |
15 |
30 |
4 |
15 |
30 |
4 |
15 |
30 |
Watts |
|
Current |
Iout
Entire Output Voltage Range |
0.13 |
0.50 |
1.0 |
0.11 |
0.42 |
0.86 |
0.10 |
0.37 |
0.75 |
mA |
|
Ripple |
Full Load, Max Eout, 300pF bypass Cap |
0.021 |
0.039 |
0.048 |
0.016 |
0.034 |
0.040 |
0.030 |
0.060 |
0.064 |
%V
p-p |
|
Ripple
with –F-M Option |
Full
Load, Max Eout, 300pF bypass Cap |
0.025 |
0.028 |
0.058 |
0.025 |
0.040 |
0.075 |
0.007 |
0.025 |
0.053 |
%V
p-p |
|
Dynamic Load Regulation |
½ to Full Load, Max Eout per .1mA |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |
V
pk |
|
Voltage Derating |
Max
Iout, Extended Input Voltage |
Figures
C & D |
Graph |
|
Line
Regulation |
Nom.
Input, Max Eout, Full Power |
<
0.01 % |
VDC |
|
Static
Load Regulation |
No
Load to Full Load, Max Eout |
<0.01% |
VDC |
|
Stability |
30
Min. warmup, per 8 hr/ per day |
<0.01% /
<0.02% |
VDC |
Output Voltage Monitor: |
All Types |
|
|
Voltage |
Full
Eout Range, Full Iout Range |
1.00 |
V
per kV |
|
Proportionality |
Full
Eout Range, Full Iout Range |
±0.1% |
V
per kV |
Remote Programming: |
All
Types |
|
|
Input
Impedance |
Nominal Input |
+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref |
MΩ |
|
Adjust
Resistance |
Typical Potentiometer Values |
10K
to 100K (Pot across Vref. & Signal GND,
Wiper to Adjust) |
Ω |
|
Adjust
Linearity |
0% to
100% |
Figure
E |
Graph |
|
Adjust
Voltage |
Referenced to signal ground |
Figure E (0 to +5 VDC) |
Graph |
|
Adjust
Logic |
0 to +5 for +Out, +5 to 0 for -Out |
+4.64
VDC for +Output or +0.36 for -Output = Nominal Eout |
|
|
Reference: |
All Types |
|
|
Output
Voltage |
T=+25°C, Initial Value |
+
5.00 ±
2% |
VDC |
|
Output
Impedance |
T=+25°C |
464
± 1% |
Ω |
|
Stability |
Over Full
Temperature
Range |
Figure
F |
Graph |
|
Enable: |
All Types |
|
Power
Supply On |
Floated, or voltage ≥ TTL High |
+2.4 to 32 |
VDC |
Power
Supply Off |
Grounded, or voltage ≤ TTL Low |
0 to + 0.7 ± 0.2 (Isink 1mA
minimum) |
VDC |
Temperature & Humidity:
|
Standard
|
-25 PPM
|
|
Humidity |
All Conditions, Standard Package |
0 to 95% non-condensing |
0
to 95% non-condensing |
|
Operating |
Full
Load, Max Eout, Case Temp. |
-40 to +65 |
+10 to +45 |
°C |
Storage |
Non-Operating, Case Temp. |
-55 to +105 |
-55 to +105 |
°C |
Coefficient |
Over
the Specified Temperature |
±50 |
±25 |
PPM/°C |
Thermal Shock |
Mil-Std 810, Method 503-4, Proc. II |
-40 to +65 |
-40 to +65 |
°C |
|
Altitude: |
All Types |
|
Operating |
Standard Package |
Sea Level through Vacuum |
|
Non-operating |
Standard Package |
Sea
Level through Vacuum |
|
|
Shock & Vibration: |
Standard |
-C Option |
|
Shock |
Mil-Std-810, Method 516.5, Proc. IV |
20 |
40 |
G's |
Vibration |
Mil-Std-810, Method 514.5, Fig. 514.5C-3 |
10 |
20 |
G's |
|
Packaging: |
|
30A/35A |
40A |
30A/35A |
40A |
|
Material |
Outer
construction |
Plastic
(DAP) ASTM-D-5948 |
Aluminum
Alloy 5052-H32, Finish: Mil-C-5541 Class 1A |
|